Type HLC-1XV04GG1.5P/40A/277VAC) Definite Purpose Contactor
Standard
IEC60947
UL508
Rating of Current Ie 40A FLA: 40A
Resistive Amps Ith 50A RES: 50A
Rating of Contacts Voltage Ue 240/277V 240/277/480/600VAC
Rating of Insulation Voltage Ui 660V 600V
Rating of Coil Voltage Us 277V Us: 277VAC 60Hz
Mechanical Life 1000,000 Cycle 1000,000 Cycle
Electricity life 100,000 Cycle 250,000 Cycle


add  to cart
 
Type And Meaning
  HLC-1XV04GG(1.5P/40A/277VAC)Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.
Product Explanation

1.Product Description

HLC-1XV04GG Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 277v, Fixed Operating Current To 40A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.


2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .